Midtherm UV - UV-C Air Purifiers
CT600
CT600 view 1
CT600 view 2
CT600 view 3

Introducing the CT600

Ceiling Tile Unit - Ultra-Quiet 600m³/h for Healthcare Environments

Ceiling-mounted UV-C air purification unit delivering year-round protection for healthcare and commercial spaces. Advanced F7 filtration captures 92-99% of airborne pollen, dust, and allergens—creating a sanctuary environment during peak allergy season (March-September). Patented single-reactor design (UK Patent GB2615993B): air passes through the filter, then through the UV-C reactor chamber destroying 99.9% of airborne bacteria, viruses, and mold. Reactor windows continuously bathe the filter surface with UV-C, preventing pathogen buildup. Ultra-quiet operation (28-34dB—quieter than a whisper) suitable for patient rooms, consultation areas, and offices. High capacity 600m³/h airflow treats rooms up to 100m². Oversized F7 filters last 6-12 months, 9,000-hour UV-C lamps. Winner of BBH 2025 Gold Award for Best Patient Safety Initiative. Designed in collaboration with NHS working group and validated at Aintree University Hospital (84-93% real-world pathogen reduction).

Capacity

600 m3/hr

Weight

30kg (23kg unit + 7kg removable cover)

Dimensions

1250mm x 650mm x 350mm overall (Plenum: 575mm x 1275mm x 300mm fits in 2-tile grid, Protrusion: 1250mm x 650mm x 50mm)

UVC Lamps

2 x 75w Phillips Signify

Sound Level

28 to 34 db (min-max speed)

Power

250w at 230v

Available Finishes

Gloss WhiteMatt Black
Key Features
  • F7 filtration captures 92-99% of pollen, dust, and allergens (ISO 16890)
  • Patented single-reactor design with dual protection (UK Patent GB2615993B)
  • Reactor destroys 99.9% of airborne pathogens + sanitizes filter via windows
  • Year-round protection: allergen reduction + infection control
  • Ultra-quiet operation (28-34dB—quieter than a whisper)
  • Discreet ceiling tile installation with only 50mm protrusion
  • Easy retrofit into standard 600x600mm ceiling grids
  • High volume air processing (600 m3/hr) treats rooms up to 100m²
  • Oversized F7 filters last 6-12 months (reduced maintenance frequency)
  • Filter fault alert lamp indicates when replacement is needed
  • UV-C lamps guaranteed for 9,000 hours (Phillips Signify)
  • Drop rod mounting system for below-ceiling maintenance
  • HTM03 Compliant for NHS healthcare facilities
  • NHS Lab Bio-Validated with 84-93% real-world pathogen reduction
Special Features
  • BBH 2025 Gold Award: Best Patient Safety Initiative (Aintree Hospital deployment)
  • UK Patent GB2615993B: Filter sanitisation technology prevents pathogen build-up
  • NHS University Hospitals of Liverpool - Aintree Hospital Project (84-93% pathogen reduction)
  • Dual protection: F7 filtration + single-reactor UV-C (air + filter sanitization)
  • Ideal for hay fever sufferers: 92-99% pollen removal during peak season (March-September)
  • Creates "pollen sanctuary" in patient rooms, consultation areas, and waiting rooms
  • Designed in collaboration with NHS Working Group for healthcare applications
  • Specifically engineered for ultra-quiet operation in patient care environments
  • Installed in Multiple NHS Trusts with proven track record

Real-World Case Studies

See the CT600 in action at real NHS facilities:

Aintree Hospital installation

Aintree University Hospital - Liverpool

Independent clinical validation by Professor Tony Fisher demonstrated 84-93% airborne pathogen reduction across four occupied NHS patient rooms. This study won the BBH 2025 Gold Award for Best Patient Safety Initiative.

Read Full Case Study →

Common Questions

How quiet is the CT600?

The CT600 operates at 28-34 dB depending on speed setting—quieter than a library (30 dB) and normal conversation (60 dB). At low speed, it's virtually silent, making it ideal for patient rooms, consultation rooms, and offices.

Is the CT600 tested by the NHS?

Yes. The CT600 underwent rigorous bio-validation testing at an NHS laboratory, demonstrating 99.9% pathogen reduction. It was also deployed in the Aintree University Hospital study and won the BBH 2025 Gold Award for Best Patient Safety Initiative.

What room sizes does the CT600 cover?

The CT600 is designed for medium-large spaces with 600m³/h capacity. It has been successfully deployed in smaller rooms at reduced speed settings, achieving ultra-quiet operation below 28dB while maintaining effective air purification.

How often do lamps need replacing?

UV-C lamps are warranted for 9,000 hours of operation. We recommend annual replacement for units running 24/7 to ensure desired performance levels. Replacement lamps are available from stock in limited quantities, with additional stock available within 5-10 days.

Installation & Technical Details

CT600 technical view 1
CT600 technical view 2
CT600 technical view 3

Interested in the CT600?

Contact us today to discuss your requirements

Cookie Consent

We use essential cookies to ensure our website functions properly. These cookies are necessary for basic site functionality and do not collect personal information. By continuing to use this site, you consent to our use of essential cookies in accordance with GDPR requirements.

We do not use tracking cookies, analytics cookies, or third-party advertising cookies. Your privacy is important to us.